MS provides highly accurate measurements of the mass-to-charge ratio (m/z) of gaseous ions in vacuum. The m/z can be used to calculate the mass of the ion and, from this, the identification of the species can often be deduced. Peptides and proteins are not volatile enough to form gaseous ions using traditional approaches; however, the advent of electrospray ionization (ESI) and MALDI has rendered these important analytes amenable to MS analysis and, along with several other innovations, led to the ongoing revolution in proteomics. In ESI, sample flows out of a capillary tube that has voltage applied at the outlet, resulting in the formation of a spray of sample droplets. As the droplets evaporate, ionized sample molecules are formed and introduced to the mass spectrometer. In MALDI, samples are cocrystallized with a radiation-absorbing molecule (matrix) of low molecular weight, such as a-cyano-4-hydroxycinnamic acid (CHCA) or 2,5-dihydroxybenzoic acid (DHB). Ionization is performed by exposing the sample to short bursts of radiation from a laser. Either ultraviolet (UV)-absorbing matrix with a UV-emitting laser (UV-MALDI) or infrared (IR)-absorbing matrix with an IR-emitting laser (IR-MALDI) can be utilized. The rapid heating caused by radiation absorption results in explosive volatilization of the matrix and formation of charged analytes in the gas state that can be transferred to the mass spectrometer. Usually, a tiny fraction of the sample is vaporized by a single laser shot, so signal from multiple shots are averaged to obtain good-quality spectra. MALDI-MS has a high mass range (routinely up to 30 kDa), good detection limits (attomol range), and high mass accuracy (0.01% at high mass).

MALDI is tolerant of additives (such as salts or surfactants) that might be contained in a sample, and is compatible with parallel analysis as discussed below. Because the sample is deposited on a surface in MALDI, the sample can be stored and reanalyzed. The latter feature enables data-dependent workflows, wherein results from an analysis can be used to determine the next type of experiment to perform on the sample. Experiments may include multidimensional MS (MSn), wherein a selected ion is degraded in the gas state by irradiation with an infrared laser or collision with neutral molecules (collision-induced dissociation), resulting in dissociation of the ion into characteristic fragments, called product ions or daughter ions, which are then analyzed. The resulting spectra can be used like puzzle pieces to identify the parent ion. Alternatively, a sample may be chemically degraded or modified, such as digestion with an enzyme, and reanalyzed providing further information.

A significant weakness of MALDI is the difficulty of quantification. As the laser spot is focused on different regions of sample, the relative amounts of analyte detected will vary. In many cases, this effect can be quite extreme so that in some regions, no signal is detected and in others, the so-called ''sweet spots,'' strong signals are observed.

ESI and MALDI have proven to be complementary in many ways.[1] Perhaps, the most important reason for both MALDI and ESI to be developed is that they appear to be effective in ionizing different classes of peptides. Thus, in analysis of complex mixtures, detected peptides will vary significantly depending on the ioniza-tion method used.[1] Therefore, application of both methods may prove effective.

Getting Started With Dumbbells

Getting Started With Dumbbells

The use of dumbbells gives you a much more comprehensive strengthening effect because the workout engages your stabilizer muscles, in addition to the muscle you may be pin-pointing. Without all of the belts and artificial stabilizers of a machine, you also engage your core muscles, which are your body's natural stabilizers.

Get My Free Ebook


Post a comment