References

1. Gibson, U.E.; Heid, C.A.; Williams, P.M. A novel method for real time quantitative RT-PCR. Genome Res. 1996, 6, 995-1001.

2. Bustin, S.A. Absolute quantification of mRNA using realtime reverse transcription polymerase chain reaction assays. J. Mol. Endocrinol. 2000, 25, 169-193.

3. Halford, W.P.; Falco, V.C.; Gebhardt, B.M.; Carr, D.J. The inherent quantitative capacity of the reverse tran-scription-polymerase chain reaction. Anal. Biochem. 1999, 266, 181-191.

4. Kappes, J.C.; Saag, M.S.; Shaw, G.M.; Hahn, B.H.; Chopra, P.; Chen, S.; Emini, E.A.; McFarland, R.; Yang, L.C.; Piatak, M., Jr. Assessment of antiretroviral therapy by plasma viral load testing: Standard and ICD HIV-1 p24 antigen and viral RNA (QC-PCR) assays compared. J. Acquir. Immune Defic. Syndr. Human Retroviral. 1995, 10, 139-149.

5. Bustin, S.A.; Dorudi, S. Molecular assessment of tumour stage and disease recurrence using PCR-based assays. Mol. Med. Today 1998, 4, 389-396.

6. Jung, R.; Soondrum, K.; Neumaier, M. Quantitative PCR. Clin. Chem. Lab. Med. 2000, 38, 833-836.

7. Wittwer, C.T.; Herrmann, M.G.; Moss, A.A.; Rasmussen, R.P. Continuous fluorescence monitoring of rapid cycle DNA amplification. BioTechniques 1997, 22, 130- 138.

8. Bomjen, G.; Raina, A.; Sulaiman, I.M.; Hasnain, S.E.; Dogra, T.D. Effect of storage of blood samples on DNA yield, quality and fingerprinting: A forensic approach. Indian J. Exp. Biol. 1996, 34, 384-386.

9. Cone, R.W.; Hobson, A.C.; Huang, M.L. Coamplified positive control detects inhibition of polymerase chain reactions. J. Clin. Microbiol. 1992, 30, 3185-3189.

10. Aatsinki, J.T.; Lakkakorpi, J.T.; Pietila, E.M.; Rajaniemi, H.J. A coupled one-step reverse transcription PCR procedure for generation of full-length open reading frames. BioTechniques 1994, 16, 282-288.

11. Mallet, F.; Oriol, G.; Mary, C.; Verrier, B.; Mandrand, B. Continuous RT-PCR using AMV-RT and Taq DNA polymerase: Characterization and comparison to uncoupled procedures. BioTechniques 1995, 18, 678687.

12. Vandesompele, J.; De Paepe, A.; Speleman, F. Elimination of primer-dimer artifacts and genomic coamplification using a two-step SYBR green I real-time RT-PCR. Anal. Biochem. 2002, 303, 95-98.

13. Lekanne Deprez, R.H.; Fijnvandraat, A.C.; Ruijter, J.M.; Moorman, A.F. Sensitivity and accuracy of quantitative real-time polymerase chain reaction using SYBR green I depends on cDNA synthesis conditions. Anal. Biochem. 2002, 307, 63-69.

14. Bebenek, K.; Abbotts, J.; Roberts, J.D.; Wilson, S.H.; Kunkel, T.A. Specificity and mechanism of error-prone replication by human immunodeficiency virus-1 reverse transcriptase. J. Biol. Chem. 1989, 264, 16948-16956.

15. Brooks, E.M.; Sheflin, L.G.; Spaulding, S.W. Secondary structure in the 3' UTR of EGF and the choice of reverse transcriptases affect the detection of message diversity by RT-PCR. BioTechniques 1995, 19, 806-815.

16. Freeman, W.M.; Vrana, S.L.; Vrana, K.E. Use of elevated reverse transcription reaction temperatures in RT-PCR. BioTechniques 1996, 20, 782-783.

17. Gerard, G.F.; Fox, D.K.; Nathan, M.; D'Alessio, J.M.

Reverse transcriptase. The use of cloned Moloney murine leukemia virus reverse transcriptase to synthesize DNA from RNA. Mol. Biotechnol. 1997, 8, 61-77.

18. Myers, T.W.; Gelfand, D.H. Reverse transcription and DNA amplification by a Thermus thermophilus DNA polymerase. Biochemistry 1991, 30, 7661-7666.

19. Harrell, R.A.; Hart, R.P. Rapid preparation of Thermus flavus DNA polymerase. PCR Methods Appl. 1994, 3, 372-375.

20. Morrison, T.B.; Weis, J.J.; Wittwer, C.T. Quantification of low-copy transcripts by continuous SYBR green I monitoring during amplification. BioTechniques 1998, 24, 954-962.

21. Ririe, K.M.; Rasmussen, R.P.; Wittwer, C.T. Product differentiation by analysis of DNA melting curves during the polymerase chain reaction. Anal. Biochem. 1997, 245, 154-160.

22. Higuchi, R.; Fockler, C.; Dollinger, G.; Watson, R. Kinetic PCR analysis: Real-time monitoring of DNA amplification reactions. Biotechnology (New York) 1993, 11, 10261030.

23. Souaze, F.; Ntodou-Thome, A.; Tran, C.Y.; Rostene, W.; Forgez, P. Quantitative RT-PCR: Limits and accuracy. BioTechniques 1996, 21, 280-285.

24. Bustin, S.A. Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): Trends and problems. J. Mol. Endocrinol. 2002, 29, 23-39.

25. Fink, L.; Seeger, W.; Ermert, L.; Hanze, J.; Stahl, U.; Grimminger, F.; Kummer, W.; Bohle, R.M. Real-time quantitative RT-PCR after laser-assisted cell picking. Nat. Med. 1998, 4, 1329-1333.

26. Pfaffl, M.W. A new mathematical model for relative quantification in real-time RT-PCR. Nucleic Acids Res.

27. Liu, W.; Saint, D.A. A new quantitative method of real time reverse transcription polymerase chain reaction assay based on simulation of polymerase chain reaction kinetics. Anal. Biochem. 2002, 302, 52-59.

28. Hocquette, J.F.; Brandstetter, A.M. Common practice in molecular biology may introduce statistical bias and misleading biological interpretation. J. Nutr. Biochem.

29. Ke, L.D.; Chen, Z.; Yung, W.K. A reliability test of standard-based quantitative PCR: Exogenous vs. endogenous standards. Mol. Cell. Probes 2000, 14, 127135.

30. Pfaffl, M.W.; Hageleit, M. Validities of mRNA quantification using recombinant RNA and recombinant DNA external calibration curves in real-time RT-PCR. Biotech-nol. Lett. 2001, 23, 275-282.

31. Thellin, O.; Zorzi, W.; Lakaye, B.; De Borman, B.; Coumans, B.; Hennen, G.; Grisar, T.; Igout, A.; Heinen, E.

Housekeeping genes as internal standards: Use and limits. J. Biotechnol. 1999, 75, 291-295.

32. Karge, W.H.; Schaefer, E.J.; Ordovas, J.M. Quantification of mRNA by polymerase chain reaction (PCR) using an internal standard and a nonradioactive detection method. Methods Mol. Biol. 1998, 110, 43-61.

33. Haberhausen, G.; Pinsl, J.; Kuhn, C.C.; Markert-Hahn, C. Comparative study of different standardization concepts in quantitative competitive reverse transcription-PCR assays. J. Clin. Microbiol. 1998, 36, 628-633.

34. Tricarico, C.; Pinzani, P.; Bianchi, S.; Paglierani, M.; Distante, V.; Pazzagli, M.; Bustin, S.A.; Orlando, C. Quantitative real-time reverse transcription polymerase chain reaction: Normalization to rRNA or single housekeeping genes is inappropriate for human tissue biopsies. Anal. Biochem. 2002, 309, 293-300.

35. Bhatia, P.; Taylor, W.R.; Greenberg, A.H.; Wright, J.A. Comparison of glyceraldehyde-3-phosphate dehydrogen-ase and 28S-ribosomal RNA gene expression as RNA loading controls for Northern blot analysis of cell lines of varying malignant potential. Anal. Biochem. 1994, 216, 223-226.

36. Solanas, M.; Moral, R.; Escrich, E. Unsuitability of using ribosomal RNA as loading control for Northern blot analyses related to the imbalance between messenger and ribosomal RNA content in rat mammary tumors. Anal. Biochem. 2001, 288, 99-102.

37. Deng, G.; Lu, Y.; Zlotnikov, G.; Thor, A.D.; Smith, H.S. Loss of heterozygosity in normal tissue adjacent to breast carcinomas. Science 1996, 274, 2057-2059.

38. Chelly, J.; Concordet, J.P.; Kaplan, J.C.; Kahn, A. Illegitimate transcription: Transcription of any gene in any cell type. Proc. Natl. Acad. Sci. U. S. A. 1989, 86, 2617-2621.

39. Sugiyama, Y.; Sugiyama, K.; Hirai, Y.; Akiyama, F.; Hasumi, K. Microdissection is essential for gene expression profiling of clinically resected cancer tissues. Am. J. Clin. Pathol. 2002, 117, 109-116.

40. Walch, A.; Specht, K.; Smida, J.; Aubele, M.; Zitzelsberger, H.; Hofler, H.; Werner, M. Tissue microdissection techniques in quantitative genome and gene expression analyses. Histochem. Cell Biol. 2001, 115, 269-276.

41. Bock, O.; Kreipe, H.; Lehmann, U. One-step extraction of RNA from archival biopsies. Anal. Biochem. 2001, 295, 116-117.

42. Lewis, F.; Maughan, N.J.; Smith, V.; Hillan, K.; Quirke, P. Unlocking the archive—Gene expression in paraffin-embedded tissue. J. Pathol. 2001, 195, 66-71.

43. Fink, L.; Kinfe, T.; Stein, M.M.; Ermert, L.; Hanze, J.; Kummer, W.; Seeger, W.; Bohle, R.M. Immunostaining and laser-assisted cell picking for mRNA analysis. Lab. Invest. 2000, 80, 327-333.

Getting Started With Dumbbells

Getting Started With Dumbbells

The use of dumbbells gives you a much more comprehensive strengthening effect because the workout engages your stabilizer muscles, in addition to the muscle you may be pin-pointing. Without all of the belts and artificial stabilizers of a machine, you also engage your core muscles, which are your body's natural stabilizers.

Get My Free Ebook


Post a comment